. R. Ale-90-]-j, . Alexander, and . Project, Specification Of The VXI Readout Mechanism, Daresbury, 1990.

[. R. Alexander, Hardware Overview Of The EUROGAM Data Acquisition System
URL : https://hal.archives-ouvertes.fr/in2p3-00004451

@. B. Cahan, J. P. Passérieux, and J. Pouthas, Low noise and large dynamic range nuclear amplifier for charge encoding

@. Ganil, Proposition d'un ensemble de production et d'accélération d'ions secondaires à GANILAvant-projet simplifié, p.4

. S. Gou-]-f, D. A. Goulding, S. M. Landis, and . Hinshaw, Large Coaxial Germanium Detectors -Correction for Balistic Deficit and Trapping Losses

S. Goulding and D. A. Landis, Signal Processing for Semiconductor Detectors, IEEE Transactions on Nuclear Science, vol.29, issue.3, pp.1125-1141, 1982.
DOI : 10.1109/TNS.1982.4336332

@. S. Hinshaw and D. A. Landis, A Practical Approach to Balistic Deficit Correction, I, E.E.E. Nucl. Sci. Symp, 1990.
DOI : 10.1109/23.106648

. F. Kno-79-]-@bullet-g and . Knoll, Radiation detection and mesurement, 1979.

R. Leo, Techniques for Nuclear and Particle Physics Experiments, 1987.
DOI : 10.1007/978-3-642-57920-2

D. -wade and . Peterson, The VMEbus Handbook, A User's Guide to the DEEE1014 and IEC 821 Microcomputer Bus, 1988.

@. J. Pouthas, B. Cahan, and J. P. Passérieux, New methods of signal processing for charge identification on a large dynamic range with silicon detectors

@. P. Rehak, E. Gatti, P. Holl, and J. Kemmer, Feedback Charge Amplifier Integrated On The Detector Wafer, Nucl. Instr and Meth, A288, pp.168-175, 1990.

R. Renaud, P. Marcheray, and B. Parmentier, Méthodes d'analyse des dispositifs de conversion A/N en régime dynamique, Onde Electrique, vol.69, issue.1, p.47, 1989.

. J. Sam-68-]-j, J. Samueli, A. Pigneret, and . Sarazin, Instrumentation électronique en physique nucléaire (Mesures de temps et d'énergie), 1968.

@. V. Radeka, Low-Noise Techniques in Detectors, Annual Review of Nuclear and Particle Science, vol.38, issue.1, pp.217-277, 1988.
DOI : 10.1146/annurev.ns.38.120188.001245

-. Hrisoho, Time domain noise calculation for the common base current amplifier configuration, Nuclear Instruments and Methods in Physics Research, vol.185, issue.1-3, pp.207-213, 1981.
DOI : 10.1016/0029-554X(81)91213-1

-. O. Deighton, A time-domain method for calculating noise of active integrators used in pulse amplitude spectrometry, Nuclear Instruments and Methods, vol.58, issue.2, pp.201-212, 1968.
DOI : 10.1016/0029-554X(68)90466-7

-. O. Deighton, Analysis of pulse-rate dependent noise and counting losses in active processor with fast recovery, Nuclear Instruments and Methods, vol.103, issue.1, pp.1-12, 1972.
DOI : 10.1016/0029-554X(72)90452-1

@. J. Ii-], F. Lund, and . Olschner, Simulation Of Charge Transport In Radiation Detectors, Nucl. Instr and Meth, Modular Amplifier System For Readout Of Silicon Strip Detectors, Nucl. Instr and Meth. A288, pp.31-34, 1990.

1. Walter, C. Kurtz, and O. Rolland, The Effect Of Velocity Saturation On Shape Of Current Signals In Silicon Detectors, Nucl. Instr and Meth An Analog Low Noise Read-Out Circuit For Semiconductor Detectors, A311, vol.14, pp.573-579, 1992.