Abstract : The barrel part of the CMS electromagnetic calorimeter consists of about 60000 PWO crystals and will be assembled in two Regional Centers, nearby Rome and at CERN. Two automatic machines have been designed to check the crystal quality before assembly. The main crystal characteristics are compared to a set of specifications included in the contract with the crystal producers. The stability and intercalibration between the two is a fundamental issue, which has to be controlled during the whole construction phase. This paper describes the checks that were made in order to cross calibrate the measurements and to guarantee a proper selection of crystals for the detector.
Complete list of metadata

Cited literature [5 references]  Display  Hide  Download

http://hal.in2p3.fr/in2p3-00021784
Contributor : Claudine Bombar <>
Submitted on : Thursday, May 13, 2004 - 4:36:55 PM
Last modification on : Friday, November 6, 2020 - 3:33:58 AM
Long-term archiving on: : Wednesday, March 31, 2010 - 2:08:29 PM

Identifiers

  • HAL Id : in2p3-00021784, version 1

Collections

Citation

E. Auffray, S. Baccaro, E. Bouquerel, F. Cavallari, G. Chevenier, et al.. Cross-calibration of two automatic quality control systems for the CMS ECAL crystals. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2004, 523, pp.355-364. ⟨in2p3-00021784⟩