Skip to Main content Skip to Navigation
Conference papers

Data quality monitoring for the D0 calorimeter

Abstract : The precision physics that is being carried out by D0 at Fermilab in the Run II of the Tevatron, requires optimal calorimeter response and resolution. To achieve a high level of calorimeter data quality a complete on-line and off-line strategy has been developed and implemented. It includes : online data monitoring and quality checking; offline data monitoring and data quality verification with physical objects; offline calorimeter failure correction; identification and removal of noisy events; special algorithms to remove sporadic and isolated "hot" cells or "hot" regions in the calorimeter; rejection of " bad" runs or portions of them based on strict requirements on unbiased physics quantities.
Complete list of metadata

http://hal.in2p3.fr/in2p3-00021998
Contributor : Sabine Starita <>
Submitted on : Wednesday, June 30, 2004 - 3:57:41 PM
Last modification on : Wednesday, October 14, 2020 - 4:00:21 AM
Long-term archiving on: : Thursday, April 1, 2010 - 2:36:48 PM

Identifiers

  • HAL Id : in2p3-00021998, version 1

Collections

LAL | CNRS | IN2P3

Citation

V. Shary. Data quality monitoring for the D0 calorimeter. International Conference on Calorimetry in High Energy Physics - CALOR2004 11, Mar 2004, Perugia, Italy. pp.205-209. ⟨in2p3-00021998⟩