Technical design and performance of the NEMO 3 detector

Abstract : The development of the NEMO3 detector, which is now running in the Frejus Underground Laboratory (L.S.M. Laboratoire Souterrain de Modane), was begun more than ten years ago. The NEMO3 detector uses a tracking-calorimeter technique in order to investigate double beta decay processes for several isotopes. The technical description of the detector is followed by the presentation of its performance.
Complete list of metadata

http://hal.in2p3.fr/in2p3-00023220
Contributor : Pascale Chambon Connect in order to contact the contributor
Submitted on : Wednesday, October 13, 2004 - 6:24:11 PM
Last modification on : Monday, March 28, 2022 - 10:44:04 AM

Links full text

Identifiers

Citation

R. Arnold, C. Augier, J. Baker, A. Barabash, Ph. Bernaudin, et al.. Technical design and performance of the NEMO 3 detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2005, 536, pp.79-122. ⟨10.1016/j.nima.2004.07.194⟩. ⟨in2p3-00023220⟩