F. J. Beekman, H. W. De-jong, and S. Van-geloven, Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation, IEEE Transactions on Medical Imaging, vol.21, issue.8, pp.867-877, 2002.
DOI : 10.1109/TMI.2002.803130

C. Bai, G. L. Zeng, and G. T. Gullberg, A slice-by-slice blurring model and kernel evaluation using the Klein-Nishina formula for 3D scatter compensation in parallel and converging beam SPECT, Physics in Medicine and Biology, vol.45, issue.5, pp.1275-1307, 2000.
DOI : 10.1088/0031-9155/45/5/314

C. E. Floyd, R. J. Jaszczak, and C. E. Coleman, Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECT, IEEE Transactions on Nuclear Science, vol.32, issue.1, pp.779-785, 1985.
DOI : 10.1109/TNS.1985.4336940

D. Lazaro, V. Breton, and I. Buvat, Feasibility and value of fully 3D Monte Carlo reconstruction in single-photon emission computed tomography, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.527, issue.1-2, pp.195-200, 2004.
DOI : 10.1016/j.nima.2004.03.119

URL : https://hal.archives-ouvertes.fr/in2p3-00012855

I. Buvat, D. Lazaro, and V. Breton, Robustness of Fully 3D Monte Carlo reconstruction in SPECT with respect to modeling errors, J. Nucl. Med, vol.45, pp.417-418, 2004.

D. Lazaro, I. Buvat, G. Loudos, D. Strul, G. Santin et al., Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging, Physics in Medicine and Biology, vol.49, issue.2, pp.271-285, 2004.
DOI : 10.1088/0031-9155/49/2/007

URL : https://hal.archives-ouvertes.fr/in2p3-00023196

S. Jan, GATE: a simulation toolkit for PET and SPECT, Physics in Medicine and Biology, vol.49, issue.19, pp.4543-4561, 2004.
DOI : 10.1088/0031-9155/49/19/007

URL : https://hal.archives-ouvertes.fr/in2p3-00021834

H. M. Hudson and R. S. Larkin, Accelerated image reconstruction using ordered subsets of projection data, IEEE Transactions on Medical Imaging, vol.13, issue.4, pp.601-609, 1994.
DOI : 10.1109/42.363108

I. T. Joliffe, Principal component analysis and exploratory factor analysis, Statistical Methods in Medical Research, vol.1, issue.1, pp.69-95, 1992.
DOI : 10.1177/096228029200100105

M. Rafecas, G. Böning, B. J. Pichler, E. Lorenz, M. Schwaiger et al., Effect of Noise in the Probability Matrix Used for Statistical Reconstruction of PET Data, IEEE Transactions on Nuclear Science, vol.51, issue.1, pp.149-156, 2004.
DOI : 10.1109/TNS.2003.822998