Skip to Main content Skip to Navigation
Journal articles

Response uniformity of the ATLAS liquid argon electromagnetic calorimeter

M. Aharrouche 1 J. Colas 1 L. Di Ciaccio 1 M. El Kacimi 1 O. Gaumer 1 M. Gouanere 1 D. Goujdami 1 R. Lafaye 1 S. Laplace 1 C. Le Maner 1 L. Neukermans 1 P. Perrodo 1 L. Poggioli 1 D. Prieur 1 H. Przysiezniak 1 G. Sauvage 1 I. Wingerter-Seez 1 R. Zitoun 1 F. Lanni L. Lu H. Ma S. Rajagopalan H. Takai A. Belymam D. Benchekroun M. Hakimi A. Hoummada Y. Gao R. Stroynowski M. Aleksa T. Carli P. Fassnacht F. Gianotti L. Hervas W. Lampl J. Collot 2 J.Y. Hostachy 2 F. Ledroit-Guillon 2 F. Malek 2 P. Martin 2 S. Viret 2 M. Leltchouk J. A. Parsons S. Simion F. Barreiro J. del Peso L. Labarga C. Oliver S. Rodier P. Barrillon C. Benchouk 3 F. Djama 3 F. Hubaut 3 E. Monnier 3 P. Pralavorio 3 D. Sauvage C. Serfon 3 S. Tisserant 3 J. Toth D. Banfi L. Carminati D. Cavalli G. Costa M. Delmastro M. Fanti L. Mandelli M. Mazzanti G. F. Tartarelli K. Kotov A. Maslennikov G. Pospelov Yu. Tikhonov C. Bourdarios 4 L. Fayard 4 D. Fournier 4 L. Iconomidou-Fayard 4 M. Kado 4 G. Parrour 4 P. Puzo 4 D. Rousseau 4 R. Sacco 4 L. Serin 4 G. Unal 4 D. Zerwas 4 B. Dekhissi J. Derkaoui A. El Kharrim F. Maaroufi W. Cleland D. Lacour 5 B. Laforge 5 I. Nikolic-Audit 5 Ph. Schwemling 5 H. Ghazlane R. Cherkaoui El Moursli A. Idrissi Fakhr-Eddine M. Boonekamp 6 N. Kerschen 6 B. Mansoulie 6 P. Meyer 6 J. Schwindlingy 6 B. Lund-Jensen 6
Abstract : The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.
Complete list of metadata

http://hal.in2p3.fr/in2p3-00170682
Contributor : Dominique Girod <>
Submitted on : Monday, September 10, 2007 - 1:32:45 PM
Last modification on : Monday, March 29, 2021 - 3:22:30 PM

Links full text

Identifiers

Citation

M. Aharrouche, J. Colas, L. Di Ciaccio, M. El Kacimi, O. Gaumer, et al.. Response uniformity of the ATLAS liquid argon electromagnetic calorimeter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2007, 582, pp.429-455. ⟨10.1016/j.nima.2007.08.157⟩. ⟨in2p3-00170682⟩

Share

Metrics

Record views

684