Skip to Main content Skip to Navigation
Reports

Results from the test bench of the Geometry Monitoring System of the ALICE Muon Spectrometer

Abstract : We present the results obtained with the test bench of the Geometry Monitoring System (GMS) for the ALICE Muon Spectrometer. It consists in a mock up, reproducing at full scale, three half planes of the chambers 6, 7 and 8 of the spectrometer. We show that the GMS is able to measure transverse displacements with an accuracy of 1.5 microm. We show also that the resolution deteriorates by a factor 3 to 4 when thermal gradients are generated.
Complete list of metadatas

Cited literature [2 references]  Display  Hide  Download

http://hal.in2p3.fr/in2p3-00193682
Contributor : Lpsc Bibliotheque <>
Submitted on : Tuesday, December 4, 2007 - 1:36:07 PM
Last modification on : Monday, July 20, 2020 - 9:18:27 AM
Long-term archiving on: : Friday, November 25, 2016 - 4:59:25 PM

File

ALICE-INT-2007-010.pdf
Files produced by the author(s)

Identifiers

  • HAL Id : in2p3-00193682, version 1

Collections

Citation

R. Tieulent, A. Béteille, J.-Y. Grossiord, V. Kakoyan, S. Kox, et al.. Results from the test bench of the Geometry Monitoring System of the ALICE Muon Spectrometer. 2007, 13 p. ⟨in2p3-00193682⟩