Evaluation of novel KEK/HPK n-in-p pixel sensors for ATLAS upgrade with testbeam - IN2P3 - Institut national de physique nucléaire et de physique des particules Accéder directement au contenu
Article Dans Une Revue Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Année : 2013

Evaluation of novel KEK/HPK n-in-p pixel sensors for ATLAS upgrade with testbeam

R. Nagai
  • Fonction : Auteur
C. Gallrapp
  • Fonction : Auteur
Y. Unno
  • Fonction : Auteur
O. Jinnouchi
  • Fonction : Auteur
Y. Takubo
  • Fonction : Auteur
K. Hanagaki
  • Fonction : Auteur
K. Hara
  • Fonction : Auteur
Y. Ikegami
  • Fonction : Auteur
N. Kimura
  • Fonction : Auteur
K. Nagai
  • Fonction : Auteur
I. Nakano
  • Fonction : Auteur
R. Takashima
  • Fonction : Auteur
S. Terada
  • Fonction : Auteur
J. Tojo
  • Fonction : Auteur
K. Yorita
  • Fonction : Auteur
S. Altenheiner
  • Fonction : Auteur
M. Backhaus
  • Fonction : Auteur
D. Forshaw
  • Fonction : Auteur
M. George
  • Fonction : Auteur
J. Janssen
  • Fonction : Auteur
J. Jentzsch
  • Fonction : Auteur
T. Lapsien
  • Fonction : Auteur
A. La Rosa
  • Fonction : Auteur
A. Macchiolo
  • Fonction : Auteur
C. Nellist
  • Fonction : Auteur
L. Rubinsky
  • Fonction : Auteur
A. Rummler
  • Fonction : Auteur
G. Troska
  • Fonction : Auteur
P. Weigell
  • Fonction : Auteur
J. Weingarten
  • Fonction : Auteur

Résumé

A new type of n-in-p planar pixel sensors have been developed at KEK/HPK in order to cope with the maximum particle fluence of 1-3×1016 1 MeV equivalent neutrons per square centimeter (neq/cm2) in the upcoming LHC upgrades. Four n-in-p devices were connected by bump-bonding to the new ATLAS Pixel front-end chip (FE-I4A) and characterized before and after the irradiation to 2×1015neq/cm2. These planar sensors are View the MathML source thick, using biasing structures made out of polysilicon or punch-through dot and isolation structures of common or individual p-stop. Results of measurements with radioactive 90Sr source and with a 120 GeV/c momentum pion beam at the CERN Super Proton Synchrotron (SPS) are presented. The common p-stop isolation structure shows a better performance than the individual p-stop design, after the irradiation. The flat distribution of the collected charge in the depth direction after the irradiation implies that the effect of charge trapping is small, at the fluence, with the bias voltage well above the full depletion voltage.

Dates et versions

in2p3-00696031 , version 1 (10-05-2012)

Identifiants

Citer

R. Nagai, J. Idárraga, C. Gallrapp, Y. Unno, A. Lounis, et al.. Evaluation of novel KEK/HPK n-in-p pixel sensors for ATLAS upgrade with testbeam. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013, 699, pp.78-83. ⟨10.1016/j.nima.2012.04.081⟩. ⟨in2p3-00696031⟩
41 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More