5th International Conference on Trapped Charged Particles and Fundamental Physics (TCP 2010), Saariselkä : Finlande (2010)
Mass measurements of short-lived nuclides using the ISOLTRAP preparation Penning trap
S. Naimi1, M. Rosenbusch, G. Audi1, K. Blaum, C. Böhm, C. Borgmann, M. Breitenfeldt, S. George, F. Herfurth, A. Herlert, M. Kowalska, S. Kreim, D. Lunney1, E. Minaya-Ramirez, D. Neidherr, L. Schweikhard, M. Wang
(2011)

For exotic nuclear species, short decay half-lives make precision mass measurements particularly challenging. Combining isobaric purification and themass measurement in the same trap may offer an interesting compromise between losses due to half-life and measurement precision. Here we discuss a mass measurement performed in a preparation Penning trap, and perform a study of the resonance lineshape.
1 :  CSNSM - Centre de Spectrométrie Nucléaire et de Spectrométrie de Masse
CSNSM SNO
Physique/Physique Nucléaire Expérimentale
Penning trap * Isobaric separation * Mass spectrometry * Ion dynamics