Mass measurements of short-lived nuclides using the ISOLTRAP preparation Penning trap

S. Naimi 1 M. Rosenbusch G. Audi 1 K. Blaum C. Böhm C. Borgmann M. Breitenfeldt S. George F. Herfurth A. Herlert M. Kowalska S. Kreim D. Lunney 1 E. Minaya-Ramirez D. Neidherr L. Schweikhard M. Wang
1 CSNSM SNO
CSNSM - Centre de Spectrométrie Nucléaire et de Spectrométrie de Masse, CSNSM - Centre de Sciences Nucléaires et de Sciences de la Matière : UMR8609
Abstract : For exotic nuclear species, short decay half-lives make precision mass measurements particularly challenging. Combining isobaric purification and themass measurement in the same trap may offer an interesting compromise between losses due to half-life and measurement precision. Here we discuss a mass measurement performed in a preparation Penning trap, and perform a study of the resonance lineshape.
Document type :
Conference papers
5th International Conference on Trapped Charged Particles and Fundamental Physics (TCP 2010), 2010, Saariselkä, Finland. 199, pp.231-240, 2011, <10.1007/s10751-011-0318-4>


http://hal.in2p3.fr/in2p3-00751268
Contributor : Christine Hadrossek <>
Submitted on : Tuesday, November 13, 2012 - 10:16:00 AM
Last modification on : Monday, October 13, 2014 - 3:43:25 PM

Identifiers

Collections

Citation

S. Naimi, M. Rosenbusch, G. Audi, K. Blaum, C. Böhm, et al.. Mass measurements of short-lived nuclides using the ISOLTRAP preparation Penning trap. 5th International Conference on Trapped Charged Particles and Fundamental Physics (TCP 2010), 2010, Saariselkä, Finland. 199, pp.231-240, 2011, <10.1007/s10751-011-0318-4>. <in2p3-00751268>

Export

Share

Metrics

Consultation de la notice

17