F. Carrel, GAMPIX: a New Gamma Imaging System for Radiological Safety and 311 Homeland Security Purposes, IEEE NSS Conference Record, 2011.
DOI : 10.1109/nssmic.2011.6154706

V. Schoepff, BOOSTER: Development of a Toolbox for Triage of Large Group of 313 Individuals Exposed to Radioactive Material, 2014.

W. Kaye, Calibration and Operation of the Polaris 18-Detector CdZnTe Array, Polaris-H Gamma-Ray Imaging Spectrometer, p.317, 2010.

H. O. Anger, Scintillation Camera, The review of scientific instruments, vol.29, p.1958
DOI : 10.1063/1.1715998

M. Ricard, Imaging of gamma emitters using scintillation cameras, Nucl. Instrum. 321 Methods Phys. Res. A, vol.527, pp.124-129, 2004.
DOI : 10.1016/j.nima.2004.03.097

O. Gal, CARTOGAM -a portable gamma camera for remote localization of 323 radioactive sources in nuclear facilities, Nucl. Instrum. Methods Phys. Res. A, vol.460, pp.138-145, 2001.

S. V. Guru, A high energy gamma camera using a multiple hole collimator and 326 PSPMT, Nucl. Instrum. Methods Phys. Res. A, vol.353, pp.328-333, 1994.
DOI : 10.1016/0168-9002(94)91668-3

M. Woodring, Advanced radiation imaging of low-intensity gamma-ray sources, p.328

, Nucl. Instrum. Methods Phys. Res. A, vol.422, p.329, 1999.

Z. He, The CSPD-2 Gamma-Ray Imaging System, IEEE TNS, vol.44, issue.3, 1997.
DOI : 10.1109/23.603776

R. Redus, A combined video and gamma ray imaging system for robots in nuclear 332 environments, Nucl. Instrum. Methods Phys. Res. A, vol.353, p.333, 1994.

V. R. Mccready, Clinical tests on a prototype semiconductor gamma-camera, p.334

, British Journal of Radiology, vol.44, pp.58-62, 1971.

Y. Eisen, A gamma camera based on CdTe detector, Nucl. Instrum. Methods 336 Phys. Res. A, vol.380, pp.474-478, 1996.
DOI : 10.1016/s0168-9002(96)00364-6

Z. He, 3-D position sensitive CdZnTe gamma-ray spectrometers, Nucl. Instrum. 338 Methods Phys. Res. A, vol.422, pp.173-178, 1999.
DOI : 10.1016/s0168-9002(98)00950-4

C. Mestais, A new design for a high resolution, high efficiency CZT gamma 340 camera detector, Nucl. Instrum. Methods Phys. Res. A, vol.458, p.341, 2001.

O. Limousin, Caliste 256: A CdTe imaging spectrometer for space science with a 342 580 µm pixel pitch, Nucl. Instrum. Methods Phys. Res. A, vol.647, p.343, 2011.

X. Llopart, Timepix, a 65k programmable pixel readout chip for arrival time, 344 energy and/or photon counting, Nucl. Instrum. Methods Phys. Res. A, vol.581, p.494, 2007.
DOI : 10.1016/j.nima.2007.08.079

M. Gmar, GAMPIX: a new generation of gamma camera, Nucl. Instrum. 347 Methods Phys. Res. A, vol.652, pp.638-640, 2011.

F. Carrel, GAMPIX: a new generation of gamma camera for hot spot 349 localisation, Proceedings of the ISOE Conference, 2010.

S. R. Gottesman and E. E. Fenimore, New family of Binary Arrays for Coded Aperture 351 Imaging, Applied Optics, vol.28, pp.4344-4352, 1989.

Z. Vykydal, Microprocessor controlled USB interface for Medipix2 detector, p.354

. Poland, , 2004.

D. Maneuski, Imaging and spectroscopic performance studies of pixelated CdTe 356 detector, Journal of Instrumentation, vol.7, 2012.

E. Fröjdh, X-ray absorption and charge transport in a pixelated CdTe detector 358 with single photon processing readout, Journal of Instrumentation, vol.7, p.359, 2011.

D. Turecek, Pixelman: a multi-platform data acquisition and processing software 360 package for Medipix2, Timepix and Medipix3 detectors, 2011.

M. Kroupa, Optimization of the spectroscopic response of the Timepix detector, p.362, 2011.

M. Filipenko, Characterization of the energy resolution and the tracking 364 capabilities of a hybrid pixel detector with CdTe-sensor layer for a possible use in a 365 neutrinoless double beta decay experiment, Eur. Phys. J. C, vol.73, p.366, 2013.

J. Jakubek, Precise energy calibration of pixel detector working in time-over-threshold 367 mode, Nucl. Instrum. Methods Phys. Res. A, vol.633, pp.262-266, 2011.

D. Turecek, Energy calibration of pixel detector working on Time-Over-369 Threshold mode using test pulses, p.370, 2011.

C. Ponchut and M. Ruat, Energy calibration of a CdTe X-ray pixel sensor hybridized to 371 a Timepix chip, 2012.

Y. Ménesguen and M. C. Lépy, Efficiency calibration and surface mapping of an 373 energy-dispersive detector with SOLEX: a compact tunable monochromatic X-ray 374 source, Nucl. Instrum. Methods Phys. Res. A, vol.695, pp.193-196, 2012.

R. Ballabriga, Medipix3:A 64 k pixel detector readout chip working in single 376 photon counting mode with improved spectrometric performance, Nucl. Instrum. 377 Methods Phys. Res. A, vol.633, pp.15-18, 2011.