The CMS trigger system

V. Khachatryan M. Besançon 1 F. Couderc 1 M. Dejardin 1 D. Denegri 1 B. Fabbro 1 J.L. Faure 1 C. Favaro 1 F. Ferri 1 S. Ganjour 1 A. Givernaud 1 P. Gras 1 G. Hamel De Monchenault 1 P. Jarry 1 E. Locci 1 M. Machet 1 J. Malcles 1 J. Rander 1 A. Rosowsky 1 M. Titov 1 A. Zghiche 1 I. Antropov 2 S. Baffioni 2 F. Beaudette 2 P. Busson 2 L. Cadamuro 2 E. Chapon 2 C. Charlot 2 T. Dahms 2 O. Davignon 2 N. Filipovic 2 A. Florent 2 R. Granier De Cassagnac 2 S. Lisniak 2 L. Mastrolorenzo 2 P. Mine 2 I.N. Naranjo 2 M. Nguyen C. Ochando 2 G. Ortona 2 P. Paganini 2 P. Pigard 2 S. Regnard 2 R. Salerno 2 J.B. Sauvan 2 Y. Sirois 2 T. Strebler 2 Y. Yilmaz 2 A. Zabi 2 J.-L. Agram 3 J. Andrea 3 A. Aubin 3 D. Bloch 3 J.-M. Brom 3 M. Buttignol 3 E.C. Chabert 3 N. Chanon 3 C. Collard 3 E. Conte 3 X. Coubez 3 J.-C. Fontaine 3 D. Gele 3 U. Goerlach 3 C. Goetzmann 3 A.-C. Le Bihan 3 J.A. Merlin 3 K. Skovpen 3 P. Van Hove 3 S. Gadrat 4 S. Beauceron 5 C. Bernet 5 G. Boudoul 5 E. Bouvier 5 C.A. Carrillo Montoya 5 R. Chierici 5 D. Contardo 5 B. Courbon 5 P. Depasse 5 H. El Mamouni 5 J. Fan 5 J. Fay 5 S. Gascon 5 M. Gouzevitch 5 B. Ille 5 F. Lagarde 5 I.B. Laktineh 5 M. Lethuillier 5 L. Mirabito 5 A.L. Pequegnot 5 S. Perries 5 J.D. Ruiz Alvarez 5 D. Sabes 5 L. Sgandurra 5 V. Sordini 5 M. Vander Donckt 5 P. Verdier 5 S. Viret 5
Abstract : This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton (heavy ion) collisions. The first level of the trigger is implemented in hardware, and selects events containing detector signals consistent with an electron, photon, muon, tau lepton, jet, or missing transverse energy. A programmable menu of up to 128 object-based algorithms is used to select events for subsequent processing. The trigger thresholds are adjusted to the LHC instantaneous luminosity during data taking in order to restrict the output rate to 100 kHz, the upper limit imposed by the CMS readout electronics. The second level, implemented in software, further refines the purity of the output stream, selecting an average rate of 400 Hz for offline event storage. The objectives, strategy and performance of the trigger system during the LHC Run 1 are described.
Complete list of metadatas

Cited literature [112 references]  Display  Hide  Download

http://hal.in2p3.fr/in2p3-01362517
Contributor : Sylvie Flores <>
Submitted on : Wednesday, December 19, 2018 - 11:36:27 AM
Last modification on : Wednesday, November 13, 2019 - 3:38:23 PM
Long-term archiving on : Wednesday, March 20, 2019 - 6:38:30 PM

File

HAL_01362517.pdf
Publisher files allowed on an open archive

Identifiers

Citation

V. Khachatryan, M. Besançon, F. Couderc, M. Dejardin, D. Denegri, et al.. The CMS trigger system. Journal of Instrumentation, IOP Publishing, 2017, 12 (01), pp.P01020. ⟨10.1088/1748-0221/12/01/P01020⟩. ⟨in2p3-01362517⟩

Share

Metrics

Record views

459

Files downloads

70