Résumé

A new step of the SPIRAL2 commissioning started in December 2015 with the acceleration of a first proton beamat the RFQ exit. A test bench, with all the different diagnostics which will be used on the SPIRAL2 accelerator, was installed directly after the first rebuncher of the MEBT line in order to qualify beams but also to test and make reliable the diagnosticmonitors. In 2016, different ion beams are qualified by the diagnostic test bench. This paper describes the results of the energy measurements done by a Time of Flightmonitor and the longitudinal measurements using a fast faraday cup.
Fichier non déposé

Dates et versions

in2p3-01366182 , version 1 (14-09-2016)

Identifiants

Citer

C. Jamet, W. Le Coz, G. Ledu, S. Loret, C. Potier de Courcy. Energy and Longitudinal Bunch Measurements at the SPIRAL2 RFQ Exit. International Beam Instrumentation Conference - IBIC 2016, ALBA Synchrotron Light Source, Sep 2016, Barcelona, Spain. pp.723-727, ⟨10.18429/JACoW-IBIC2016-WEPG42⟩. ⟨in2p3-01366182⟩