Production of Sc medical radioisotopes with proton and deuteron beams

Abstract : Proton and deuteron beams extracted from the PETtrace medical cyclotron at the Radiopharmaceuticals Production and Research Centre in the University of Warsaw, Heavy Ion Laboratory, 28 MeV protons from the C30 cyclotron at the National Centre for Nuclear Research, Świerk, near Warsaw and 33 MeV protons from the Arronax accelerator, Nantes were used to produce and investigate the medically interesting Sc radioisotopes. Both natural and isotopically enriched CaCO3 targets and highly enriched 48TiO2 targets were used. The production efficiency and isotopic purity were determined and are reported here for the highest commercially available enrichments of the target material. The Thick Target Yield, Activities at the End of Bombardment (EOB) and the relative activities of produced impurities at EOB are reported for 43Sc, 44gSc, 44mSc and 47Sc produced with particle energies below 30 MeV.
Document type :
Journal articles
Complete list of metadata

http://hal.in2p3.fr/in2p3-01951123
Contributor : Arnaud Guertin <>
Submitted on : Tuesday, January 26, 2021 - 3:53:54 PM
Last modification on : Tuesday, February 2, 2021 - 4:17:22 PM

File

ARI 2 200708.pdf
Files produced by the author(s)

Identifiers

Citation

Mateusz Sitarz, Katarzyna Szkliniarz, Jerzy Jastrzębski, Jarosław Choiński, Arnaud Guertin, et al.. Production of Sc medical radioisotopes with proton and deuteron beams. Applied Radiation and Isotopes, Elsevier, 2018, 142, pp.104-112. ⟨10.1016/j.apradiso.2018.09.025⟩. ⟨in2p3-01951123⟩