R. Asgari, Semiconductor backend flip chip processing, inspection requirements and challenges, 27th Annual IEEE/SEMI International Electronics Manufacturing Technology Symposium, pp.18-22, 2002.
DOI : 10.1109/IEMT.2002.1032716

[. Basolo, XPAD: pixel detector for material sciences, IEEE Transactions on Nuclear Science, vol.52, issue.5, pp.1994-1998, 2005.
DOI : 10.1109/TNS.2005.856818

URL : https://hal.archives-ouvertes.fr/in2p3-00025405

M. Bech, X-ray imaging with the PILATUS 100k detector. Nuclear Instruments and Methods in Physics Research A, pp.474-478, 2008.

E. Belau and R. Klanner, Charge collection in silicon strip detectors. Nuclear Instruments and Methods, pp.253-260, 1983.

L. Blanquart, XPAD, a new read-out pixel chip for X-ray counting, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149), pp.92-97, 2000.
DOI : 10.1109/NSSMIC.2000.949877

G. Bolla, Sensor development for the CMS pixel detector. Nuclear Instruments and Methods in Physics Research A, pp.89-99, 2002.

V. Bonvicini, . Pindo, and . Redaelli, Junction and interdiode capacitance of silicon pixel arrays. Nuclear Instruments and Methods in Physics Research A, pp.88-91, 1995.

C. Brönnimann, Protein crystallography with the PILATUS 1M detector at the Swiss Light Source, Synchrotron Radiation News, vol.55, issue.2, 2004.
DOI : 10.1107/S0021889800005732

R. N. Bracewell, The Fourier Transform and Its Applications, American Journal of Physics, vol.34, issue.8, 2000.
DOI : 10.1119/1.1973431

Z. Y. Chang and . Sansen, Low-Noise Wide-Band Amplifiers in Bipolar and CMOS Technologies, 1991.
DOI : 10.1007/978-1-4757-2126-3

E. Charbon, Substrate Noise -Analysis and Optimization for IC Design, 2003.

L. Chen, A high/speed ratio continuous-time CMOS current comparator, IEEE Electronic Circuits and Systems, vol.2, pp.883-886, 2000.

L. Chen, . Shi, and . Lu, A high speed/power ratio continuous-time CMOS current comparator, The 7th International Conference on Electronic, Circuits and Ssystems, pp.883-886, 2000.

]. D. Chr99 and . Christian, Development of a pixel readout chip for btev. Nuclear Instruments and Methods in Physics Research A, pp.144-152, 1999.

C. Claeys and E. Simoen, Radiation effects in advanced semiconductor materials and devices, 2002.
DOI : 10.1007/978-3-662-04974-7

J. C. Dainty and R. H. Shaw, Image science : principles, analysis and evaluation of photographic. Academic press, 1974.

P. Delpierre, Large surface X-ray pixel detector, IEEE Transactions on Nuclear Science, tome, vol.1, issue.3, pp.22-25, 2000.
URL : https://hal.archives-ouvertes.fr/in2p3-00012293

P. Delpierre, Large surface X-ray pixel detector, IEEE Transactions on Nuclear Science, vol.2, pp.902-905, 2002.
URL : https://hal.archives-ouvertes.fr/in2p3-00012293

P. Delpierre, PIXSCAN : pixel detector CT-scanner for small animal imaging . Nuclear Instruments and Methods in Physics Research A, pp.425-428, 2007.
URL : https://hal.archives-ouvertes.fr/hal-00319721

B. Dinkespiler, Matrice de cellules électroniques, 2008.

C. Enz and E. Vittoz, Charge-Based MOS Transistor Modeling, 2006.
DOI : 10.1002/0470855460

M. J. Flynn and . Samei, Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems, Medical Physics, vol.3031, issue.8, pp.1612-1623, 1999.
DOI : 10.1118/1.598656

J. Giersch, The influence of energy weighting on X-ray imaging quality. Nuclear Instruments and Methods in Physics Research A, pp.68-74, 2004.

B. Gilbert, The multi-tanh principle: a tutorial overview, IEEE Journal of Solid-State Circuits, vol.33, issue.1, 1998.
DOI : 10.1109/4.654932

B. Gilbert, Aspects of noise. Dans École d'été "Low noise, low offset analog IC design, EPFL, vol.5, pp.103-111, 2007.

A. L. Goertzen, A comparison of x-ray detectors for mouse CT imaging, Physics in Medicine and Biology, vol.49, issue.23, pp.5251-5265, 2004.
DOI : 10.1088/0031-9155/49/23/004

]. F. Gou82, D. A. Goulding, and . Landis, Signal processing for semiconductor detectors, IEEE Transaction on Nuclear Science, tome, vol.29, issue.3, pp.1125-1141, 1982.

P. Greer and T. V. Doorn, Evaluation of an algorithm for the assessment of the MTF using an edge method, Medical Physics, vol.19, issue.9, pp.2048-2059, 2000.
DOI : 10.1118/1.1288682

]. E. Hei80 and . Heijne, A silicon surface barrier microstrip detectors designed for high energy physics. Nuclear Instruments and Methods, pp.331-343, 1980.

P. Holl, A double-sided silicon strip detector with capacitive readout and a new method of integrated bias coupling, IEEE Transactions on Nuclear Science, vol.36, issue.1, pp.251-255, 1989.
DOI : 10.1109/23.34444

T. E. Hui, A mouse model for calculating cross-organ beta doses from yttrium-90 labeled immunoconjugates. Fourth Conference on Radioimmunodetection and Radioimmunotherapy of Cancer, pp.951-957, 1992.

S. Kavadias, . Misiakos, and . Loukas, Calculation of pixel detector capacitances through three dimensional numerical solution of the Laplace equation, IEEE Transactions on Nuclear Science, vol.41, issue.2, p.41397, 1994.
DOI : 10.1109/23.281533

. Kay, Methodology for the digital autozero calibration of analog circuits and systems. Dans École d'été "Low noise, low offset analog IC design, EPFL, pp.3-7

J. Kemmer, Fabrication of low noise silicon radiation detectors by the planar process. Nuclear Instruments and Methods, pp.499-502, 1980.

O. Klein and T. Nishina, Über die streuung von strahlung durch freie elektronen nach der neuen relativistischen quantendynamik von Dirac, Zeitschrift für Physik, pp.11-12853, 1929.

[. Kotter and M. Langer, Digital radiography with large-area flat-panel detectors, European Radiology, vol.12, issue.10, pp.2562-2570, 2002.
DOI : 10.1007/s00330-002-1350-1

Y. Koudobine, Electronique de comptage de photons pour détecteurs à pixels hybrides, Thèse de doctorat, 2005.

E. Kraft, Counting and Integrating Readout for Direct Conversion X-ray Imaging: Concept, Realization and First Prototype Measurements, IEEE Transactions on Nuclear Science, vol.54, issue.2, pp.383-390, 2007.
DOI : 10.1109/TNS.2007.891571

M. Le-bellac, Quantum Physics, 2006.
DOI : 10.1017/CBO9780511616471

]. G. Lut99 and . Lutz, Semiconductor radiation detectors. 2ème impression, 1999.

]. D. Mar01, J. F. Marsh, and . Malone, Methods and materials for the measurement of subjective and objective measurements of image quality, Radiation Protection Dosimetry, vol.94, pp.37-42, 2001.

B. Mikulec, X-ray imaging using single photon processing with semiconductor pixel detectors. Nuclear Instruments and Methods in Physics Research A, pp.282-286, 2003.

E. Mollick, Establishing Moore's law. IEEE annals of the history of computing, pp.62-75, 2006.

D. Niederlöhner, The energy weighting technique : measurements and simulations. Nuclear Instruments and Methods in Physics Research A, pp.37-41, 2005.

H. Nilsson, C. Fröjdh, and . Dubaric, Monte Carlo simulation of charge sharing effects in silicon and GaAs photon-counting X-ray imaging detectors, IEEE Transactions on Nuclear Science, vol.51, issue.4, pp.1636-1640, 2004.
DOI : 10.1109/TNS.2004.832577

P. Pangaud, XPAD3 : a new photon counting chip for X-ray CT-scanner. Nuclear Instruments and Methods in Physics Research A, pp.321-324, 2007.
URL : https://hal.archives-ouvertes.fr/in2p3-00114034

P. Pangaud, XPAD3-S : a fast hybrid pixel readout chip for X-ray synchrotron facilities. Nuclear Instruments and Methods in Physics Research A, pp.159-162, 2008.
URL : https://hal.archives-ouvertes.fr/in2p3-00266598

V. Radeka, Signal, Noise and Resolution in Position-Sensitive Detectors, IEEE Transactions on Nuclear Science, vol.21, issue.1, pp.51-64, 1974.
DOI : 10.1109/TNS.1974.4327444

V. Radeka, Signal processing for radiation detectors. tome 1. CERN, Mars, 1986.

B. Razavi, Design of analog CMOS integrated circuits, 1900.

V. Rosso, Preliminary Study of the advantages of X-ray energy selection in CT imaging. Nuclear Instruments and Methods in Physics Research A, pp.270-273, 2007.

E. Samei, Performance of digital radiographic detectors : factors affecting sharpness and noise Advances in digital radiography, pp.49-61, 2003.

W. Sansen, Design of analog integrated circuits and systems, 1994.

W. Schockley and W. T. Read, Statistics of the Recombinations of Holes and Electrons, Physical Review, vol.87, issue.5, p.835, 1952.
DOI : 10.1103/PhysRev.87.835

K. Siegbahn, Alpha-, Beta-and Gamma-ray spectroscopy. North Holland publishing company, 1965.

H. Spieler, Semiconductor detectors and electronics. TRIUMF Summer Institute, 2007.

G. Temes and K. Haug, Improved offset-compensation schemes for switchedcapacitors circuits. Electronic letters, pp.508-509, 1984.

G. Temes and W. H. Ki, Offset-compensated switched-capacitors integrators, Proc. Int. Symp. on circuits and systems, pp.2829-2832, 1990.

G. Temes, Charge injection and clock feedthrough. Dans École d'été "Low noise, low offset analog IC design, EPFL, pp.3-7, 2007.

[. Toumazou, F. J. Lidgey, and D. G. Haigh, Analog IC design : the current-mode approach, 1990.

H. Traff, Novel approach to high speed CMOS current comparators, Electronics Letters, vol.28, issue.3, p.310, 1992.
DOI : 10.1049/el:19920192

Y. Tsividis, Operation and modeling of the MOS transistor, 2003.

W. Wunstorf, Radiation hardness of silicon detectors : current status. Nuclear Instruments and Methods in Physics Research A, pp.806-814, 1997.

J. Yorkston, Recent developments in digital radiography detectors. Nuclear Instruments and Methods in Physics Research A, pp.974-985181, 2007.

C. Benoît, 27 ans Microélectronique et instrumentation Formations ans) Thèse en microélectronique et instrumentationÉtude et réalisation d'une électronique rapide à bas bruit pour un détecteur de rayons-X à pixels hybrides destiné à l'imagerie du petit animal, 2005.

. Pangaud, . Basolo, J. C. Chantepie, . Clémens, . Delpierre et al., First results of XPAD3, a new photon counting chip for X-ray CT-scanner with energy discrimination, in Conf. Rec. of, XPAD3-S : A fast hybrid pixel readout chip for X-ray synchrotron facilities. Nuclear Instruments and Methods in Physics Research A, pp.14-18159, 2007.

S. Basolo, J. F. Berar, . Boudet, . Breugnon, J. C. Chantepie et al., A 20k pixels CdTe photon-counting imager using XPAD chip. Nuclear Instruments and Methods in Physics Research A, pp.589268-274, 2008.

P. Delpierre, J. F. Basolo, . Bérar, . Bordesoule, . Boudet et al., XPAD : A photons counting pixel detector for material sciences and small animal-imaging. Nuclear Instruments and Methods in Physics Research A, pp.572250-253, 2007.
URL : https://hal.archives-ouvertes.fr/in2p3-00114589

P. Delpierre, . Debarbieux, J. F. Basolo, . Bérar, . Bonissent et al., PIXSCAN : Pixel detector CTscanner for small-animal imaging, Nuclear Instruments and Methods in Physics Research A, pp.571-572, 2007.