159 articles – 2000 Notices  [english version]
HAL : in2p3-00399922, version 1

Fiche détaillée  Récupérer au format
Physical Review A 79 (2009) 053824
Laser with an in-loop relative frequency stability of 1.0×10−21 on a 100-ms time scale for gravitational-wave detection
F. Acernese, M. Alshourbagy, F. Antonucci, S. Aoudia1, K. G. Arun2, P. Astone, G. Ballardin, F. Barone, L. Barsotti, M. Barsuglia3, Th. S. Bauer, S. Bigotta, S. Birindelli1, M. A. Bizouard2, C. Boccara4, F. Bondu1, L. Bonelli, L. Bosi, S. Braccini, C. Bradaschia, A. Brillet1, V. Brisson2, H. J. Bulten, D. Buskulic5, G. Cagnoli, E. Calloni1, E. Campagna, B. Canuel, F. Carbognani, L. Carbone, F. Cavalier, R. Cavalieri, G. Cella, E. Cesarini, E. Chassande-Mottin3, S. Chatterji, F. Cleva1, E. Coccia, J. Colas, M. Colombini, C. Corda, A. Corsi, F. Cottone, J.-P. Coulon1, E. Cuoco, S. D'Antonio, A. Dari, V. Dattilo, M. Davier2, R. De Rosa1, M. Del Prete, L. Di Fiore, A. Di Lieto, M. Di Paolo Emilio, A. Di Virgilio, V. Fafone, I. Ferrante, F. Fidecaro, I. Fiori, R. Flaminio6, J.-D. Fournier1, S. Frasca, F. Frasconi, L. Gammaitoni, F. Garufi1, G. Gemme1, E. Genin, A. Gennai, A. Giazotto, M. Granata, V. Granata5, C. Greverie1, G. Guidi, H. Heitmann1, P. Hello2, S. Hild, D. Huet, P. La Penna, M. Laval1, N. Leroy2, N. Letendre5, M. Lorenzini, V. Loriette, G. Losurdo, J.-M. Mackowski6, E. Majorana, N. Man1, M. Mantovani, F. Marchesoni, F. Marion5, J. Marque, F. Martelli, A. Masserot5, F. Menzinger, C. Michel6, L. Milano1, Y. Minenkov, S. Mitra1, M. Mohan, Julien Moreau4, N. Morgado6, A. Morgia, S. Mosca1, B. Mours5, I. Neri, F. Nocera, G. Pagliaroli, C. Palomba, F. Paoletti, S. Pardi1, A. Pasqualetti, R. Passaquieti, D. Passuello, G. Persichetti1, F. Piergiovanni, L. Pinard6, R. Poggiani, M. Punturo, P. Puppo, O. Rabaste, P. Rapagnani, T. Regimbau1, F. Ricci, A. Rocchi, L. Rolland5, R. Romano, P. Ruggi, B. Sassolas6, D. Sentenac, B. L. Swinkels, R. Terenzi, A. Toncelli, M. Tonelli, E. Tournefier5, F. Travasso, J. Trummer5, G. Vajente, J. F. J. Van Den Brand, S. Van Der Putten, D. Verkindt5, F. Vetrano, A. Viceré, J.-Y. Vinet1, H. Vocca, M. Was2, M. Yvert5
VIRGO Collaboration(s)
(2009)

We report on the stabilization of the laser frequency for the Virgo gravitational-wave detector. We have obtained a frequency noise level, measured in loop, of 1.9×10−7 Hz/sqrt(Hz) at 10 Hz for the 1064 nm laser; this value is limited by shot noise. The Allan standard deviation for relative frequency noise is 1.0×10−21 on a 100-ms time scale. The spectral density of the laser frequency noise is negligible in the channel where gravitational waves ought to appear and meets the specifications for the target spectral resolution of the Virgo interferometer in the 10 Hz-10 kHz detection bandwidth.
1 :  ARTEMIS - Astrophysique Relativiste Théories Expériences Métrologie Instrumentation Signaux
2 :  LAL - Laboratoire de l'Accélérateur Linéaire
3 :  APC - UMR 7164 - AstroParticule et Cosmologie
4 :  ESPCI ParisTech
5 :  LAPP - Laboratoire d'Annecy le Vieux de Physique des Particules
6 :  LMA - Laboratoire des matériaux avancés
APC - Cosmologie et Gravitation
APC - ADAMIS
virgo
Physique/Physique/Instrumentations et Détecteurs