Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider
Repond J., Yu J., Hawkes C.M., Mikami Y., Miller O. et al
Journal of Instrumentation 3 (2008) P08001 - http://hal.in2p3.fr/in2p3-00284842
Physique/Physique/Instrumentations et Détecteurs
Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider
J. Repond, J. Yu, C.M. Hawkes, Y. Mikami, O. Miller, N.K. Watson, J.A. Wilson, G. Mavromanolakis, M.A. Thomson, D.R. Ward, W. Yan, F. Badaud1, D. Boumediene1, C. Cârloganu1, R. Cornat1, P. Gay1, Ph. Gris1, S. Manen1, F. Morisseau1, L. Royer1, G.C. Blazey, D. Chakraborty, A. Dyshkant, K. Francis, D. Hedin, G. Lima, V. Zutshi, J.Y. Hostachy2, L. Morin2, E. Garutti3, V. Korbel3, F. Sefkow3, M. Groll, G. Kim, D.-W. Kim, K. Lee, S. Yip Lee, K. Kawagoe, Y. Tamura, M. Magnan, C. Noronha, H. Yilmaz, O. Zorba, V. Bartsch, J.M. Butterworth, M. Postranecky, M. Warren, M. Wing, M. Faucci Giannelli, M.G. Green, F. Salvatore, T. Wu, D. Bailey, R.J. Barlow, M. Kelly, S. Snow, R.J. Thompson, M. Danilov, V. Kochetkov, N. Baranova, P. Ermolov, D. Karmanov, M. Korolev, M. Merkin, A. Voronin, B. Bouquet4, S. Callier4, F. Dulucq4, J. Fleury4, H. Li4, G. Martin-Chassard4, F. Richard4, Ch. de La Taille4, R. Poeschl4, L. Raux4, M. Ruan4, N. Seguin-Moreau4, F. Wicek4, Z. Zhang4, M. Anduze5, V. Boudry5, J.-C. Brient5, C. Clerc5, G. Gaycken5, C. Jauffret5, A. Karar5, P. Mora Defreitas5, G. Musat5, M. Reinhard5, A. Rougé5, A.L. Sanchez5, J-Ch. Vanel5, H. Videau5, J. Zacek, J. Cvach, P. Gallus, M. Havranek, M. Janata, M. Marcisovsky, I. Polak, J. Popule, L. Tomasek, M. Tomasek, P. Ruzicka, P. Sicho, J. Smolik, V. Vrba, J. Zalesak, Yu. Arestov, A. Baird, R.N. Halsall, S.W. Nam, I.H. Park, J. Yang
1 :  LPC - Laboratoire de Physique Corpusculaire [Clermont-Ferrand]
http://clrwww.in2p3.fr/
CNRS : UMR6533 – IN2P3 – Université Blaise Pascal - Clermont-Ferrand II
Campus des Cézeaux 24, avenue des Landais BP 80026 63171 Aubière Cedex
France
2 :  LPSC - Laboratoire de Physique Subatomique et de Cosmologie
http://lpsc.in2p3.fr
CNRS : UMR5821 – IN2P3 – Université Joseph Fourier - Grenoble I – Institut Polytechnique de Grenoble - Grenoble Institute of Technology
53 avenue des Martyrs - 38026 Grenoble Cedex
France
3 :  DESY - Deutsches Elektronen-Synchrotron [Zeuthen]
http://www.desy.de/
Helmholtz-Gemeinschaft – Deutsches Elektronen-Synchrotron
Platanenallee 6 D-15738 Zeuthen
Allemagne
4 :  LAL - Laboratoire de l'Accélérateur Linéaire
http://www.lal.in2p3.fr/
CNRS : UMR8607 – IN2P3 – Université Paris XI - Paris Sud
Centre Scientifique d'Orsay B.P. 34 91898 ORSAY Cedex
France
5 :  LLR - Laboratoire Leprince-Ringuet
http://polywww.in2p3.fr/
CNRS : UMR7638 – IN2P3 – Polytechnique - X
Route de Saclay - 91128 Palaiseau Cedex
France
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.
CALICE

Articles dans des revues avec comité de lecture
2008
Journal of Instrumentation
Publisher Institute of Physics: Hybrid Open Access
ISSN 1748-0221 
3
P08001

LPSC0865, LAL 08-57
33 pages, 34 figures, Accept. in JINST
Calorimeters – Detector alignment and calibration methods – Detector design and construction technologies and materials
Lien vers le texte intégral : 
http://fr.arXiv.org/abs/0805.4833