Performance and Applications of the CdTe- and Si-XPAD3 photon counting 2D detector
Medjoubi K., Hustache S., Picca F., Bérar J.-F., Boudet N. et al
Dans Journal of Instrumentation - 12 th International Workshop on Radiation Imaging Detectors (iWoRiD 2010), Cambridge : Royaume-Uni (2010) - http://hal.in2p3.fr/in2p3-00559508
Sciences du Vivant/Ingénierie biomédicale
Sciences de l'ingénieur/Electronique
Performance and Applications of the CdTe- and Si-XPAD3 photon counting 2D detector
K. Medjoubi ()1, S. Hustache1, F. Picca1, Jean-François Bérar2, Nathalie Boudet2, 3, F. Bompard4, P. Breugnon4, J. -C. Clémens4, A. Dawiec4, P. Delpierre4, B. Dinkespiler4, S. Godiot4, J. -P. Logier4, M. Menouni4, C. Morel4, M. Niclas4, P. Pangaud4, E. Vigeolas4
1 :  SSOLEIL - Synchrotron SOLEIL
http://www.synchrotron-soleil.fr
CNRS : UR1
L'Orme des Merisiers Saint-Aubin - BP 48 91192 GIF-sur-YVETTE CEDEX
France
2 :  NEEL - Institut Néel
http://www.neel.cnrs.fr/
CNRS : UPR2940 – Université Joseph Fourier - Grenoble I – Institut National Polytechnique de Grenoble (INPG)
25 avenue des Martyrs - BP 166 38042 GRENOBLE CEDEX 9
France
3 :  CESR - Centre d'étude spatiale des rayonnements
http://www.cesr.fr
CNRS : UMR5187 – Observatoire Midi-Pyrénées – INSU – Université Paul Sabatier (UPS) - Toulouse III
9 Av du colonel Roche - BP 4346 31028 TOULOUSE CEDEX 4
France
4 :  CPPM - Centre de Physique des Particules de Marseille
http://marwww.in2p3.fr/
CNRS : UMR7346 – IN2P3 – Université de la Méditerranée - Aix-Marseille II
163, avenue de Luminy - Case 902 - 13288 Marseille cedex 09
France
CRG
The XPAD3 is the third generation of a single photon counting chip developed in collaboration by SOLEIL Synchrotron, the Institut Néel and the Centre de Physique de Particules de Marseille (CPPM). The chip contains 9600 pixels of 130 mmside and a counting electronic chain with an adjustable low level threshold in each pixel. Imaging and detection performance (detective quantum efficiency, modulation transfer function and energy resolution) of the XPAD3 detectors hybridized with Si and CdTe sensors have been evaluated and compared using monochromatic synchrotron X-rays beam. A second version of the chip, optimized for pump-probe experiments, has been realized and successfully tested. Three 7.3 cm x 12.5 cm Si-XPAD3 imagers, composed of 8 silicon modules (7 chips per module) and one 2.1 cm x 3.1 cm CdTe-XPAD3 imager (4 chips) have been constructed and successfully used for synchrotron diffraction experiments and biomedical imaging.

Communications avec actes
2011
2010
Journal of Instrumentation
internationale
61
2011 IOP Publishing Ltd and SISSA

12 th International Workshop on Radiation Imaging Detectors (iWoRiD 2010)
Cambridge
Royaume-Uni
11/07/2010
15/07/2010
Medjoubi M.

29.40.Wk Solid-state detectors
X-ray detectors – Hybrid detectors – X-ray radiography – digital radiography (DR)