s'authentifier
version française rss feed
HAL : in2p3-00666179, version 1

Fiche concise  Récupérer au format
Optimization of the hadron calorimeter geometry for the SiD detector
Blaha J., Karyotakis Y.
Rapport de recherche (2011) 13 - http://hal.in2p3.fr/in2p3-00666179
Physique/Physique/Instrumentations et Détecteurs
Optimization of the hadron calorimeter geometry for the SiD detector
J. Blaha1, Y. Karyotakis1
1 :  LAPP - Laboratoire d'Annecy le Vieux de Physique des Particules
http://wwwlapp.in2p3.fr/
CNRS : UMR5814 – IN2P3 – Université de Savoie
9 Chemin de Bellevue - BP 110 - 74941 Annecy-le-Vieux CEDEX - France
France
The aim of this study is to find an optimal mechanical design of the hadronic calorimeter for SiD detector which takes into account engineering as well as physics requirements. The study focuses on comparison of the physics performance of the several various calorimeter mechanical designs. Therefore, the quantities shuch as energy shower shape, containment, calorimeter response, linearity and energy resolution have been evaluated.

Rapport de recherche
2011
13

LAPP-TECH-2011-03