Towards a Sub-Millimeter PET Prototype with Continuous LYSO Crystals and SiPM Matrices
Llosa G., Barrillon P., Barrio J., G. Bisogni M., Cabello J. et al
2012 Nuclear Science Symposium, Medical Imaging Conference and 19th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors (2012 IEEE NSS/MIC/RTSD), Anaheim : États-Unis (2012) - http://hal.in2p3.fr/in2p3-00747624
Sciences de l'ingénieur/Micro et nanotechnologies/Microélectronique
Towards a Sub-Millimeter PET Prototype with Continuous LYSO Crystals and SiPM Matrices
G. Llosa1, P. Barrillon2, J. Barrio1, M. G. Bisogni3, J. Cabello1, A. Del Guerra3, A. Etxebeste1, J. E. Gillam1, C. Lacasta1, C. de La Taille2, J. F. Oliver1, M. Rafecas1, C. Solaz1, V. Stankova1
1 :  IFIC - Instituto de Fisica Corpuscular
http://ific.uv.es/
Consejo Superior de Investigaciones Cientificas – Universidad de Valencia
Edificio Institutos de Investigación Apartado de Correos 22085 46071 Valencia
Espagne
2 :  LAL - Laboratoire de l'Accélérateur Linéaire
http://www.lal.in2p3.fr/
CNRS : UMR8607 – IN2P3 – Université Paris XI - Paris Sud
Centre Scientifique d'Orsay B.P. 34 91898 ORSAY Cedex
France
3 :  INFN, Sezione di Pisa - Istituto Nazionale di Fisica Nucleare, Sezione di Pisa
http://www.pi.infn.it/
INFN
Edificio C Polo Fibonacci Largo B. Pontecorvo, 3 56127 Pisa
Italie
Omega
A small animal PET prototype with continuous LYSO crystals coupled to silicon photomultipliers has been developed at IFIC, Valencia. The system consists of two detector heads attached to a rotating stage. Each detector head is composed of a continuous 12 mm x 12 mm crystal painted white, coupled to a monolithic silicon photomultiplier matrix. Tests with 5 mm and 10 mm thick crystals have been carried out. The matrix has 8x8 pixel elements of 1.4 mm x 1.5 mm size in a 1.5mm x 1.5mm pitch. The intrinsic spatial resolution of the detectors is around 0.7 mm FWHM both for the 5 mm and the 10 mm thick crystals. The simulated one-pass list mode (SOPL) algorithm is employed for image reconstruction to fully exploit the continuous nature of the data. The FWHM of the reconstructed point-like sources is better than 1 mm FWHM, which make us confident that sub-millimeter spatial resolution can be achieved in PET images.