45 articles – 154 Notices  [english version]
HAL : in2p3-00026007, version 1

Fiche détaillée  Récupérer au format
6th Edoardo Amaldi Conference on Gravitational Waves, Okinawa : Japan
The Virgo automatic alignment system
F. Acernese, P. Amico, M. Al-Shourbagy, S. Aoudia1, S. Avino, D. Babusci, G. Ballardin, R. Barillé, F. Barone, L. Barsotti, M. Barsuglia2, F. Beauville3, M.A. Bizouard2, C. Boccara4, F. Bondu1, L. Bosi, C. Bradaschia, S. Braccini, A. Brillet1, V. Brisson2, L. Brocco, D. Buskulic3, E. Calloni, E. Campagna, F. Cavalier2, R. Cavalieri, G. Cella, E. Chassande-Mottin1, C. Corda, A.-C. Clapson2, F. Cleva1, J.-P. Coulon1, E. Cuoco, V. Dattilo, M. Davier2, R. De Rosa, L. Di Fiore, A. Di Virgilio, B. Dujardin1, A. Eleuteri, D. Enard, I. Ferrante, F. Fidecaro, I. Fiori, R. Flaminio3, J.-D. Fournier1, S. Frasca, F. Frasconi, A. Freise, L. Gammaitoni, A. Gennai, A. Giazotto, G. Giordano, L. Giordano, R. Gouaty3, D. Grosjean3, G. Guidi, S. Hebri, H. Heitmann1, P. Hello2, L. Holloway, S. Kreckelbergh2, P. La Penna, V. Loriette4, M. Loupias, G. Losurdo, J.-M. Mackowski5, E. Majorana, C.N. Man1, M. Mantovani, F. Marchesoni, F. Marion3, J. Marque, F. Martelli, A. Masserot3, M. Mazzoni, L. Milano, C. Moins, Julien Moreau4, N. Morgado5, B. Mours3, A. Pai, C. Palomba, F. Paoletti, S. Pardi, A. Pasqualetti, R. Passaquieti, D. Passuello, B. Perniola, F. Piergiovanni, L. Pinard5, R. Poggiani, M. Punturo, P. Puppo, K. Qipiani, P. Rapagnani, V. Reita4, A. Remillieux5, F. Ricci, I. Ricciardi, P. Ruggi, G. Russo, S. Solimeno, A. Spallicci1, R. Stanga, R. Taddei, D. Tombolato, M. Tonelli, A. Toncelli, E. Tournefier3, F. Travasso, G. Vajente, D. Verkindt3, F. Vetrano, A. Viceré, J.-Y. Vinet1, H. Vocca, M. Yvert3, Z. Zhang
VIRGO Collaboration(s)
(2006)

The automatic alignment system of the Virgo interferometer differs substantially from those used in similar experiments, since it uses a variant of the Anderson technique. This implies a completely different control topology with respect to other detectors, and the main feature is a strong coupling of different degrees of freedom in the optical signals. It also provides two extra output ports in which differential wave-front sensors can be placed, namely the light transmitted by the Fabry–Perot arm cavities. We report on the first experimental demonstration of this technique on a large scale recycled interferometer, and on the present status of the automatic alignment system.
1 :  ARTEMIS - Astrophysique Relativiste Théories Expériences Métrologie Instrumentation Signaux
2 :  LAL - Laboratoire de l'Accélérateur Linéaire
3 :  LAPP - Laboratoire d'Annecy le Vieux de Physique des Particules
4 :  ESPCI ParisTech
5 :  LMA - Laboratoire des matériaux avancés
virgo
Physique/Physique/Instrumentations et Détecteurs