| Thème(s) : |
 |
|
 |
| Titre : |
 |
Lock acquisition of the Virgo gravitational wave detector |
 |
| Auteur : |
 |
F. Acernese1, M. Alshourbagy, P. Amico, F. Antonucci, S. Aoudia2, K.G. Arun3, P. Astone, S. Avino, L. Baggio4, G. Ballardin, F. Barone1, L. Barsotti, M. Barsuglia5, Th.S. Bauer, S. Bigotta, S. Birindelli, M.A. Bizouard3, C. Boccara1, F. Bondu2, L. Bosi, S. Braccini, C. Bradaschia, A. Brillet2, V. Brisson3, D. Buskulic4, G. Cagnoli, E. Calloni, E. Campagna, F. Carbognani, F. Cavalier3, R. Cavalieri, G. Cella, E. Cesarini, E. Chassande-Mottin5, S. Chatterji, F. Cleva2, E. Coccia, C. Corda, A. Corsi, F. Cottone, J.-P. Coulon2, E. Cuoco, S. D&rsquoantonio, A. Dari, V. Dattilo, M. Davier3, R. De Rosa, M. Del Prete, L. Di Fiore, A. Di Lieto, M. Di Paolo Emilio, A. Di Virgilio, M. Evans, V. Fafone, I. Ferrante, F. Fidecaro, I. Fiori, R. Flaminio6, J.-D. Fournier2, S. Frasca, F. Frasconi, L. Gammaitoni, F. Garufi, E. Genin, A. Gennai, A. Giazotto, V. Granata4, C. Greverie2, D. Grosjean4, G. Guidi, S. Hamdani, S. Hebri, H. Heitmann2, P. Hello3, D. Huet, S. Kreckelbergh3, P. La Penna, M. Laval2, N. Leroy3, N. Letendre4, B. Lopez, M. Lorenzini, V. Loriette1, G. Losurdo, J.-M. Mackowski6, E. Majorana, C.N. Man2, M. Mantovani, F. Marchesoni, F. Marion4, J. Marque, A. Masserot4, F. Menzinger, C. Michel6, L. Milano, Y. Minenkov, S. Mitra2, M. Mohan, Julien Moreau1, N. Morgado6, S. Mosca, B. Mours4, I. Neri, F. Nocera, G. Pagliaroli, C. Palomba, F. Paoletti, S. Pardi, A. Pasqualetti, R. Passaquieti, D. Passuello, F. Piergiovanni, L. Pinard6, R. Poggiani, M. Punturo, P. Puppo, O. Rabaste5, P. Rapagnani, T. Regimbau2, F. Ricci, I. Ricciardi, A. Rocchi, L. Rolland4, R. Romano1, P. Ruggi, D. Sentenac, S. Solimeno, B.L. Swinkels, R. Terenzi, A. Toncelli, M. Tonelli, E. Tournefier4, F. Travasso, G. Vajente, J.F.J. van den Brand, S. Van Der Putten, D. Verkindt4, F. Vetrano, A. Viceré, J.-Y. Vinet2, H. Vocca, M. Yvert4 |
 |
| Laboratoire : |
 |
|
 |
| équipe(s) de recherche : |
 |
APC - Cosmologie et Gravitation APC - ADAMIS virgo |
| Résumé : |
 |
The Virgo interferometer for gravitational wave detection has concluded four months of scientific data acquisition in its final optical configuration (a power-recycled interferometer with Fabry-Perot cavities in the arms). The lock acquisition technique developed to bring and keep the Virgo detector on its working point largely proved to be very efficient and robust. In this paper we describe the variable finesse lock acquisition technique and we discuss the performance of the whole locking system. |
 |
| Collaboration/Projet : |
 |
VIRGO |
 |
|
| Type de publication : |
 |
Articles dans des revues avec comité de lecture |
 |
Date de publication ou d'écriture : |
 |
2008 |
 |
| Nom du périodique : |
 |
| Astroparticle Physics (Astropart. Phys.) |
| Publisher |
Elsevier |
| ISSN |
0927-6505 |
|
 |
| Volume : |
 |
30 |
 |
| Page/Article : |
 |
29-38 |
 |
|
| Identifiant local : |
 |
LAL 08-124 |
 |
| Mot(s)-clé(s) : |
 |
Gravitational wave detectors – Interferometry – Control systems – Lock acquisition |
 |