45 articles – 154 Notices  [english version]
HAL : in2p3-00552235, version 1

Fiche détaillée  Récupérer au format
Classical and Quantum Gravity 28 (2011) 025005
Calibration and sensitivity of the Virgo detector during its second science run
T. Accadia1, F. Acernese, F. Antonucci, P. Astone, G. Ballardin, F. Barone, M. Barsuglia2, A. Basti, Th.S. Bauer, M.G. Beker, A. Belletoile1, S. Birindelli3, M. Bitossi, M.A. Bizouard4, M. Blom, F. Bondu, L. Bonelli, R. Bonnand5, V. Boschi, L. Bosi, B. Bouhou2, S. Braccini, C. Bradaschia, A. Brillet3, V. Brisson4, R. Budzy?ski, T. Bulik, H.J. Bulten, D. Buskulic1, C. Buy2, G. Cagnoli, E. Calloni, E. Campagna, B. Canuel, F. Carbognani, F. Cavalier4, R. Cavalieri, G. Cella, E. Cesarini, O. Chaibi, E. Chassande-Mottin2, A. Chincarini, F. Cleva3, E. Coccia, C.N. Colacino, J. Colas, A. Colla, M. Colombini, A. Corsi, J.-P. Coulon3, E. Cuoco, S. D&rsquoantonio, V. Dattilo, M. Davier4, R. Day, R. De Rosa, G. Debreczeni, M. Del Prete, L. Di Fiore, A. Di Lieto, M. Di Paolo Emilio, A. Di Virgilio, A. Dietz1, M. Drago, V. Fafone, I. Ferrante, F. Fidecaro, I. Fiori, R. Flaminio5, L.A. Forte, J.-D. Fournier3, J. Franc5, S. Frasca, F. Frasconi, A. Freise, M. Galimberti5, L. Gammaitoni, F. Garufi, M.E. Gáspár, G. Gemme, E. Genin, A. Gennai, A. Giazotto, R. Gouaty1, M. Granata2, C. Greverie3, G.M. Guidi, J.-F. Hayau, H. Heitmann3, 6, P. Hello4, S. Hild, D. Huet, P. Jaranowski, I. Kowalska, A. Królak, N. Leroy4, N. Letendre1, T.G.F. Li, N. Liguori, M. Lorenzini, V. Loriette, G. Losurdo, E. Majorana, I. Maksimovic7, N. Man3, M. Mantovani, F. Marchesoni, F. Marion1, J. Marque, F. Martelli, A. Masserot1, C. Michel5, L. Milano, Y. Minenkov, M. Mohan, N. Morgado, A. Morgia, S. Mosca, V. Moscatelli, B. Mours1, I. Neri, F. Nocera, G. Pagliaroli, L. Palladino, C. Palomba, F. Paoletti, S. Pardi, M. Parisi, A. Pasqualetti, R. Passaquieti, D. Passuello, G. Persichetti, M. Pichot3, F. Piergiovanni, M. Pietka, L. Pinard5, R. Poggiani, M. Prato, G.A. Prodi, M. Punturo, P. Puppo, D.S. Rabeling, I. Rácz, P. Rapagnani, V. Re, T. Regimbau3, F. Ricci, F. Robinet4, A. Rocchi, L. Rolland1, R. Romano, D. Rosiska, P. Ruggi, B. Sassolas5, D. Sentenac, L. Sperandio, R. Sturani, B. Swinkels, A. Toncelli, M. Tonelli, O. Torre, E. Tournefier1, F. Travasso, G. Vajente, J.F.J. van den Brand, S. Van Der Putten, M. Vasuth, M. Vavoulidis4, G. Vedovato, D. Verkindt1, F. Vetrano, A. Viceré, J.-Y. Vinet3, H. Vocca, R.L. Ward2, M. Was4, M. Yvert1
VIRGO Collaboration(s)
(2011)

The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, 6 months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data and the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency domain is described and typical sensitivities measured during VSR2 are shown.
1 :  LAPP - Laboratoire d'Annecy le Vieux de Physique des Particules
2 :  APC - UMR 7164 - AstroParticule et Cosmologie
3 :  OCA - Observatoire de la Cote d'Azur
4 :  LAL - Laboratoire de l'Accélérateur Linéaire
5 :  LMA - Laboratoire des matériaux avancés
6 :  IPR - Institut de Physique de Rennes
7 :  ESPCI ParisTech
APC - Cosmologie et Gravitation
APC - ADAMIS
Planète et Univers/Astrophysique/Instrumentation et méthodes pour l'astrophysique

Physique/Astrophysique/Instrumentation et méthodes pour l'astrophysique

Physique/Physique/Instrumentations et Détecteurs