10th Edition of Faible Tension Faible Consommation, Marrakech : Maroc (2011)
Low power CMOS potentiostat for three electrodes amperometric chemical sensor
P.-A. Boutet1, S. Manen1
(2011)

This paper presents two front-end electronics architectures, called potentiostats, developed for measuring gas concentrations with electro-chemical sensors. These potentiostats are designed to be integrated in wireless embedded systems. Consequently, the total power consumption is critical. An amperometric three-electrodes electro-chemical sensor has been chosen since it is powerless. Its electrical model has been determined in order to optimize the readout electronics associated. Two potentiostats have been realized in a 0.35µm CMOS process. The most power consumption optimized architecture designed in this work presents a consumption of 10.8µW over a range of detection included from 70nA to 25µA.
1 :  LPC-CLERMONT - Laboratoire de Physique Corpusculaire de Clermont-Ferrand
Sciences de l'ingénieur/Micro et nanotechnologies/Microélectronique
CMOS