Publications du LPSC
Consultation
Tous les documents
Par année de publication
Par domaine arXiv
Par discipline IN2P3
Par type de document
Par auteurs du labo
Rechercher
811 articles – 5040 Notices
[english version]
.:.
Consultation
>
Par domaine arXiv
> Physique Médicale .:.
23 documents classés par :
Date
Titre
Nom du premier auteur
Type de documents
Date de dépôt
1
-
2
Experimental results and first 22Na source image reconstruction by two prototype modules in coincidence of a liquid xenon positron emission tomograph for small animal imaging
Gallin-Martel M.L., Grondin Y., Gac N., Carcagno Y., Gallin-Martel L. et al
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
682
(2012) 66-74 [hal-00703776 - version 1]
Prospectives accélérateurs pour les applications en santé et énergie
Baylac M.
Journées Prospective IN2P3-IRFU
, France (2012) [in2p3-00685415 - version 1]
Interfaces physique médecine/imagerie médicale/TEP
Arnoud Y.
Ecole de Physique Avancée au Maghreb 2011 " Hautes Energies - Cosmologie et Astroparticules - Instrumentation associée "
, Morocco (2011) [in2p3-00582887 - version 1]
TraDeRa: développement d'un détecteur pour le contrôle qualité IMRT en ligne et en temps réel
Fonteille I.
9èmes Journées Scientifiques de la Société Française de Physique Médicale
, France (2010) [in2p3-00486702 - version 1]
Hadrontherapy
Collot J.
FKPPL Workshop
, France (2009) [in2p3-00365327 - version 1]
Integrated electronics for a CdTe based PET system
Rossetto O., Rostaing J.P., Richer J.P., Billoint O., Bouvier J. et al
In
2009 Conference Record IEEE
-
2009 IEEE Nuclear Science Symposium and Medical Imaging Conference
, United States (2009) [in2p3-00426390 - version 1]
A liquid Xenon Positron Emission Tomograph for small animal imaging : first experimental results of a prototype cell
Gallin-Martel M.L., Gallin-Martel L., Grondin Y., Rossetto O., Collot J. et al
Nuclear Instruments and Methods in Physics Research Research: Accelerators, Spectrometers, Detectors and Associated Equipment
599
(2009) 275-283 [in2p3-00331510 - version 1]
Towards the variable energy extraction from a medical FFAG
Pasternak J., Méot F.
In
The International Workshop on FFAG Accelerators
-
FFAG Workshop'06
, Japan (2006) [in2p3-00191066 - version 1]
Spiral FFAG acelerator for cancer therapy
Pasternak J.
Semi-Annual International Workshop on FFAG
, France (2007) [in2p3-00169523 - version 1]
Comparison of hadrontherapy installation methods
Méot F.
Semi-Annual International Workshop on FFAG
, France (2007) [in2p3-00169519 - version 1]
The FFAG R&D and medical application project RACCAM
Autin B., Collot J., Fourrier J., Froidefond E., Martinache F. et al
In
Proceedings of the EPAC'06
-
European Particle Accelerator Conference EPAC'06
, United Kingdom (2006) [in2p3-00096870 - version 1]
Magnet simulations for medical FFAG
Autin B., Froidefond E.
In
Proceedings of the EPAC'06
-
European Particle Accelerator Conference (EPAC'06)
, United Kingdom [in2p3-00083756 - version 1]
Uniform, variable size rectangle beam scanning. Application to hadrontherapy
Méot F.
Nuclear Instruments and Methods in Physics Research Research: Accelerators, Spectrometers, Detectors and Associated Equipment
564
(2006) 108-114 [in2p3-00087410 - version 1]
Experimental study of a liquid Xenon PET prototype module
Gallin-Martel M.L., Martin P., Mayet F., Ballon J., Barbier G. et al
In
Nuclear Instruments and Methods in Physics Research A
-
7th International Workshop on Radiation Imaging Detectors (IWORID-7)
, France [in2p3-00024907 - version 2]
GePEToS : A Geant4 Monte Carlo simulation package for Positron Emission Tomography
Jan S., Collot J., Gallin-Martel M.L., Martin P., Mayet F. et al
IEEE Transactions on Nuclear Science
52
(2005) 102-106 [hal-00000917 - version 1]
Status of the "ETOILE" project for a French Hadrontherapy Centre
Bajard M., De Conto J.M., Remillieux J.
Radiotherapy and Oncology
73 Suppl. 2
(2004) S211-S215 [in2p3-00024563 - version 1]
Optimisation of X-ray spectra for osteodensitometry and body composition measurements : theoretical study and experimental validation
Herve L., Robert-Coutant C., Dinten J.M., Comparat V.
In
Penetrating Radiation Systems and Applications IV
-
SPIE Annual Meeting on Penetrating Radiation Systems and Applications
, United States [in2p3-00020290 - version 1]
Study of arterial blood pressure by a Windkessel-type model : influence of arterial functional properties
Diourte B., Siche J.P., Comparat V., Baguet J.P., Mallion J.M.
Computer Methods and Programs in Biomedicine
60
(1999) 11-22 [in2p3-00003214 - version 1]
Modelisation et simulation du systeme cardiovasculaire par analogie electrique
Diourte B.
In
5emes Journees des Jeunes Chercheurs
-
Journees des Jeunes Chercheurs.5
, France [in2p3-00000885 - version 1]
Non-invasive ambulatory blood pressure variability and cardiac baroreflec sensitivity
Siche J.P., Herpin D., Asmar R.G., Poncelet P., Chamontin B. et al
Journal of Hypertension
13
(1995) 1654-1659 [in2p3-00003212 - version 1]