| $\beta$-Imaging with the PIM device |
|
|
| J. Samarati1G. CharpakP. CoulonM. LeguayP. LerayS. Lupone1L. Luquin1V. Metivier1M. MeynadierE. Morteau1D. Thers1 |
|
|
| (2004) |
|
|
| The $\beta$ autoradiography is an imaging technique which allows the two dimensional localisation of the distribution of a molecule labelled with 3H or 14C in tissue sample. In collaboration with the Biospace Mesures company, we developed a new micropattern gaseous detector called Parallel Ionization Multiplier (PIM) dedicated to the $\beta$ imaging. The images obtained show characteristics in adequation with the autoradiography requirements as a 2D spatial resolution (FWHM) of Click to view the MathML source (respectively Click to view the MathML source) and an efficiency of 85% (respectively 50%) for 3H (respectively 14C). |
|
|
|
|
|
|
|
|
|
|
| 1 : | SUBATECH - Laboratoire SUBATECH Nantes |
|
|
|
|
|
|
|
|
| Thème(s) | : | Physique/Physique/Instrumentations et Détecteurs |
|
|
| β Particles – PIM – Spatial resolution |