Response uniformity of the ATLAS liquid argon electromagnetic calorimeter - IN2P3 - Institut national de physique nucléaire et de physique des particules Access content directly
Journal Articles Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Year : 2007

Response uniformity of the ATLAS liquid argon electromagnetic calorimeter

M. Aharrouche (1) , J. Colas (1) , L. Di Ciaccio (1) , M. El Kacimi (1) , O. Gaumer (1) , M. Gouanere (1) , D. Goujdami (1) , R. Lafaye (1) , S. Laplace (1) , C. Le Maner (1) , L. Neukermans (1) , P. Perrodo (1) , L. Poggioli (1) , D. Prieur (1) , H. Przysiezniak (1) , G. Sauvage (1) , I. Wingerter-Seez (1) , R. Zitoun (1) , F. Lanni , L. Lu , H. Ma , S. Rajagopalan , H. Takai , A. Belymam , D. Benchekroun , M. Hakimi , A. Hoummada , Y. Gao , R. Stroynowski , M. Aleksa , T. Carli , P. Fassnacht , F. Gianotti , L. Hervas , W. Lampl , J. Collot (2) , J.Y. Hostachy (2) , F. Ledroit-Guillon (2) , F. Malek (2) , P. Martin (2) , S. Viret (2) , M. Leltchouk , J. A. Parsons , S. Simion , F. Barreiro , J. del Peso , L. Labarga , C. Oliver , S. Rodier , P. Barrillon , C. Benchouk (3) , F. Djama (3) , F. Hubaut (3) , E. Monnier (3) , P. Pralavorio (3) , D. Sauvage , C. Serfon (3) , S. Tisserant (3) , J. Toth , D. Banfi , L. Carminati , D. Cavalli , G. Costa , M. Delmastro , M. Fanti , L. Mandelli , M. Mazzanti , G. F. Tartarelli , K. Kotov , A. Maslennikov , G. Pospelov , Yu. Tikhonov , C. Bourdarios (4) , L. Fayard (4) , D. Fournier (4) , L. Iconomidou-Fayard (4) , M. Kado (4) , G. Parrour (4) , P. Puzo (4) , D. Rousseau (4) , R. Sacco (4) , L. Serin (4) , G. Unal (4) , D. Zerwas (4) , B. Dekhissi , J. Derkaoui , A. El Kharrim , F. Maaroufi , W. Cleland , D. Lacour (5) , B. Laforge (5) , I. Nikolic-Audit (5) , Ph. Schwemling (5) , H. Ghazlane , R. Cherkaoui El Moursli , A. Idrissi Fakhr-Eddine , M. Boonekamp (6) , N. Kerschen (6) , B. Mansoulie (6) , P. Meyer (6) , J. Schwindlingy (6) , B. Lund-Jensen (6)
F. Lanni
  • Function : Author
L. Lu
  • Function : Author
H. Ma
  • Function : Author
S. Rajagopalan
  • Function : Author
H. Takai
  • Function : Author
A. Belymam
  • Function : Author
D. Benchekroun
  • Function : Author
M. Hakimi
  • Function : Author
A. Hoummada
  • Function : Author
Y. Gao
  • Function : Author
R. Stroynowski
  • Function : Author
M. Aleksa
  • Function : Author
T. Carli
  • Function : Author
P. Fassnacht
  • Function : Author
F. Gianotti
  • Function : Author
L. Hervas
  • Function : Author
W. Lampl
  • Function : Author
M. Leltchouk
  • Function : Author
J. A. Parsons
  • Function : Author
S. Simion
  • Function : Author
F. Barreiro
  • Function : Author
J. del Peso
  • Function : Author
L. Labarga
  • Function : Author
C. Oliver
  • Function : Author
S. Rodier
  • Function : Author
P. Barrillon
  • Function : Author
D. Sauvage
  • Function : Author
J. Toth
  • Function : Author
D. Banfi
  • Function : Author
L. Carminati
  • Function : Author
D. Cavalli
  • Function : Author
G. Costa
  • Function : Author
M. Delmastro
  • Function : Author
M. Fanti
  • Function : Author
L. Mandelli
  • Function : Author
M. Mazzanti
  • Function : Author
G. F. Tartarelli
  • Function : Author
K. Kotov
  • Function : Author
A. Maslennikov
  • Function : Author
G. Pospelov
  • Function : Author
Yu. Tikhonov
  • Function : Author
D. Rousseau
B. Dekhissi
  • Function : Author
J. Derkaoui
  • Function : Author
A. El Kharrim
  • Function : Author
F. Maaroufi
  • Function : Author
W. Cleland
  • Function : Author
H. Ghazlane
  • Function : Author
R. Cherkaoui El Moursli
  • Function : Author
A. Idrissi Fakhr-Eddine
  • Function : Author

Abstract

The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.

Dates and versions

in2p3-00170682 , version 1 (10-09-2007)

Identifiers

Cite

M. Aharrouche, J. Colas, L. Di Ciaccio, M. El Kacimi, O. Gaumer, et al.. Response uniformity of the ATLAS liquid argon electromagnetic calorimeter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007, 582, pp.429-455. ⟨10.1016/j.nima.2007.08.157⟩. ⟨in2p3-00170682⟩
63 View
0 Download

Altmetric

Share

Gmail Mastodon Facebook X LinkedIn More