Position resolution of the prototype AGATA triple-cluster detector from an in-beam experiment

F. Recchia
  • Fonction : Auteur
D. Bazzacco
  • Fonction : Auteur
E. Farnea
  • Fonction : Auteur
A. Gadea
  • Fonction : Auteur
R. Venturelli
  • Fonction : Auteur
T. Beck
  • Fonction : Auteur
P. Bednarczyk
  • Fonction : Auteur
A. Buerger
  • Fonction : Auteur
A. Dewald
  • Fonction : Auteur
M. Dimmock
  • Fonction : Auteur
G. Duchene
J. Eberth
  • Fonction : Auteur
J. Gerl
  • Fonction : Auteur
R. Gernhaeuser
  • Fonction : Auteur
K. Hauschild
A. Holler
  • Fonction : Auteur
P. Jones
  • Fonction : Auteur
T. Kroll
  • Fonction : Auteur
R. Krucken
  • Fonction : Auteur
N. Kurz
  • Fonction : Auteur
J. Ljungvall
S. Lunardi
  • Fonction : Auteur
P. Maierbeck
  • Fonction : Auteur
D. Mengoni
  • Fonction : Auteur
J. Nyberg
  • Fonction : Auteur
L. Nelson
  • Fonction : Auteur
G. Pascovici
  • Fonction : Auteur
P. Reiter
  • Fonction : Auteur
H. Schaffner
  • Fonction : Auteur
M. Schlarb
  • Fonction : Auteur
T. Steinhardt
  • Fonction : Auteur
O. Thelen
  • Fonction : Auteur
C.A. Ur
  • Fonction : Auteur
J.J.V. Dobon
  • Fonction : Auteur
D. Weisshaar

Résumé

AGATA belongs to a new generation of gamma-ray detector arrays for nuclear spectroscopy at present in its final stage of development. The detectors of these new arrays will be based on 36-fold electronically segmented coaxial germanium diodes operated in position sensitive mode. An in-beam test of the AGATA prototype triple cluster detector was carried out with the purpose of demonstrating the feasibility of such detectors and in order to measure the most sensitive parameters for their overall performance. An inverse kinematics reaction was performed, using a (48)Ti beam at an energy of 100MeV, impinging on a deuterated titanium tat-get. The results from the analysis of the experimental data, compared with the predictions of Monte Carlo Simulations, give an estimation of the position sensitivity of these detectors of about 5 mm FWHM, consistent with the specifications required. (C) 2009 Elsevier B.V. All rights reserved.

Dates et versions

in2p3-00685733 , version 1 (05-04-2012)

Identifiants

Citer

F. Recchia, D. Bazzacco, E. Farnea, A. Gadea, R. Venturelli, et al.. Position resolution of the prototype AGATA triple-cluster detector from an in-beam experiment. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009, 604, pp.555-562. ⟨10.1016/j.nima.2009.02.042⟩. ⟨in2p3-00685733⟩